Back to Waterproofing
Mapei Mapelastic Foundation, cementitious membrane: the pack
Mapei's own picture. The pack we stock: Part A 22 kg · Part B 10 kg.

Mapei · Cementitious membraneNo. 40 / 47

Mapelastic Foundation

Two-component, flexible cementitious mortar for waterproofing concrete surfaces subject to both positive and negative water pressure.

Two-component, flexible cementitious mortar for waterproofing concrete surfaces subject to both positive and negative water pressure

  • Waterproofing concrete and masonry structures subject to positive or negative hydrostatic pressure
  • It is recommended for foundation walls, car-parks and underground environments, basins, channels and swimming pools
  • Waterproofing concrete retaining walls
  • Waterproofing underground car-parks, cellars, sunken swimming pools and basins and lift pits against the counter-pressure of water
  • Waterproofing breeze-block walls pre-treated with a suitable MAPEI mortar
Consumption
About 1.65 kg/m² per mm by roller
Packs we stock
Part A 22 kg · Part B 10 kg

Related documentation

  • Technical data sheet

    Edition 2069-10-2025 en (IT) · 6 pages · 1.4 MB · PDF

    DownloadOpen
  • Safety data sheet

    Sent by WhatsApp or email

    Request

Mapei's own document, unaltered, saved on 2026-11-05. Mapei revises its data sheets: ask us for the current edition before you specify.

Coverage calculator

The arithmetic uses Mapei's published consumption for Mapelastic Foundation and the pack sizes we stock. Set your own wastage allowance.

m²
mm

Data sheet: The final thickness must be at least 2 mm.

Application
%

You need

3

x 32 kg kit (A 22 kg + B 10 kg)

Data sheet quantity
66 kg
With 10% wastage
72.6 kg
Send this to WhatsApp for a quote

The figures behind it.

  • Roller application: approx. 1.65 kg/m² per mm thickness.
  • Spray application with rendering machine: approx. 1.75 kg/m² per mm thickness on flat surfaces
  • approx. 2.1 kg/m² per mm thickness on rough surfaces with irregularities

Consumption on site depends on the substrate, the tool and the applicator, which is why wastage is yours to set. The result is a quantity to plan and quote with, not a guarantee of coverage. Confirm the system against the current Mapei technical data sheet before ordering.

Application

In Mapei's own words, from the technical data sheet.

  1. 01Waterproofing concrete and masonry structures subject to positive or negative hydrostatic pressure
  2. 02It is recommended for foundation walls, car-parks and underground environments, basins, channels and swimming pools
  3. 03Waterproofing concrete retaining walls
  4. 04Waterproofing underground car-parks, cellars, sunken swimming pools and basins and lift pits against the counter-pressure of water
  5. 05Waterproofing breeze-block walls pre-treated with a suitable MAPEI mortar

Where it is not the right product.

  • Do not use Mapelastic Foundation for coatings with a high thickness (more than 2 mm per coat)
  • Do not apply Mapelastic Foundation at temperatures below +5°C
  • Do not apply Mapelastic Foundation on substrates saturated with water (surfaces must dry off before application)
  • Do not add cement, aggregates or water to Mapelastic Foundation
  • Protect from rain and water contact for the first 24 hours after application

Specification

  • EN 1504-2 · Complies with the requirements of EN 1504-2 Standards, PI, MC and IR principles
  • EN 14891 · EN 14891 (CM01P)
  • EN 1504-9 · Mapelastic Foundation fulfils all the main criteria for the EN 1504-9 Standards
  • EMICODE · EC1 Plus - very low emission
  • EN 1062-1 (test method EN 1062-3) · W < 0,07 kg/m²·h0,5 Class W3 (low water permeability) according to EN 1062-1)
  • EN 1062-7 · Class A4 (+23°C) (> 1,25 mm)
  • EN ISO 7783 · Sd < 3 m Class I (permeable to water vapour)
  • EN 13501-1 · Euroclass E
Mixing ratio
component A : component B = 2.2 : 1 (one 22 kg bag of component A with one 10 kg can of component B)
Layer thickness
final thickness not less than 2mm
Permissible application temperature
room and substrate temperature from +5°C to +35°C
Recommended application temperature range
from +5°C to +40°C
Mix density
1650 kg/m³
Pot life of mix
approx. 60 mins.
Manual application
Mapelastic Foundation must be applied with a roller or a trowel within 60 minutes of it being mixed in at least two coats, to give a final thickness of at least 2 mm.
The second coat
may be applied approximately 6 hours after the first coat
Spray application
The final thickness must be at least 2 mm. After applying the first layer, wait until it has cured (approximately 6 hours) and then apply a second layer.
Impermeability to water under pressure (5 bar for 3 days) of positive lift expressed as water penetration
no penetration
Impermeability to water under pressure (1.5 bar) of negative lift expressed as water penetration
no penetration
Static crack-bridging at +23 °C
Class A4 (+23°C) (> 1,25 mm)

Typical values as Mapei prints them in data sheet edition 2069-10-2025 en (IT). They are not a specification for your project: the current Mapei data sheet is.

On site

Packs, mixing and storage.

We stock
Part A 22 kg · Part B 10 kg
Mapei packaging
32 kg kits: component A: 22 kg bags; component B: 10 kg tanks.
Mixing
component A : component B = 2.2 : 1 (one 22 kg bag of component A with one 10 kg can of component B)
Storage
Mapelastic Foundation component A may be stored for 12 months in its original packaging in a dry place. Mapelastic Foundation component B may be stored for 24 months.

Mapelastic Foundation in Tanzania

Tell us the area. We will quote the job.

Sahihi is an authorized Mapei distributor in Dar es Salaam. Send the quantity of Mapelastic Foundation you need, or describe the job and we will work it out with you.